OSVersion Operating system version of the computer system
generating the indication in the format,
ProviderVersion 2.2.0.0
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain 3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
Note: When ImpactedDomain is 3 (Enclosure) the
properties indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Physical Disk F/W version string
HWLogicalLocation Physical Disk Location string
For example, Port:1E Box: 1 Bay 5
HWPhysicalLocation Physical Location of the Failed Drive (Bay Number)
HWSerialNumber Physical Disk Serial Number
HP_DeviceIndication
DeviceModel Physical Disk Model string
DeviceControllerLogicalLocation Controller Location
For example, SmartArray 642 in Slot 2