Smart Array 97
4-4-3 HP_DeviceIndication: Physical Drive Status
Changed to REBUILDING
Table 4-97 HP_DeviceIndication: Physical Drive Status Changed to REBUILDING
Property name Property implementation
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain 3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
Note: When ImpactedDomain is 3 (Enclosure) the
properties indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Physical Disk F/W version string
HWLogicalLocation Physical Disk Location string
HWPhysicalLocation Physical Location of the Failed Drive (Bay Number)
HWSerialNumber Physical Disk Serial Number
VariableNames[] FailureDescription
DriveInterface
LastFailureDescription
VariableTypes[] String (1)
VariableValues[] FailureDescription short description of the failure
Drive interface HPSA_DiskDrive.DriveInterface
LastFailureDescription – last failure reason string from
the drive. HPSA_DiskDrive.OperationalStatus[1]
HP_DeviceIndication