Fan optionsFan options
CAUTION:CAUTION: To avoid damage to the equipment, do not operate the server for extended periods of time if the server does not
have the optimal number of fans installed. Although the server might boot, Hewlett Packard Enterprise does not
recommend operating the server without the required fans installed and operating.
The server supports standard and high performance fans. Use the following tables to identify the valid fan configurations.
Table 1. Table 1. Standard fan configurationStandard fan configuration
Drive configurationDrive configuration Fan bay 1Fan bay 1 Fan bay 2Fan bay 2 Fan bay 3Fan bay 3 Fan bay 4Fan bay 4 Fan bay 5Fan bay 5 Fan bay 6Fan bay 6 Fan bay 7Fan bay 7
4 LFF Optional Optional Fan Fan Fan Fan Fan
8 SFF Optional Optional Fan Fan Fan Fan Fan
Table 2. Table 2. High performance fan configurationHigh performance fan configuration
Drive configurationDrive configuration Fan bay 1Fan bay 1 Fan bay 2Fan bay 2 Fan bay 3Fan bay 3 Fan bay 4Fan bay 4 Fan bay 5Fan bay 5 Fan bay 6Fan bay 6 Fan bay 7Fan bay 7
4 LFF Fan Fan Fan Fan Fan Fan Fan
12 LFF Fan Fan Fan Fan Fan Fan Fan
8 SFF Fan Fan Fan Fan Fan Fan Fan
The server supports variable fan speeds. The fans operate at minimum speed until a temperature change requires a fan speed increase to
cool the server. The server shuts down during the following temperature-related scenarios:
At POST and in the OS, iLO 6 performs an orderly shutdown if a cautionary temperature level is detected. If the server hardware detects
a critical temperature level before an orderly shutdown occurs, the server performs an immediate shutdown.
When the Thermal Shutdown feature is disabled in the BIOS/Platform Configuration (RBSU), iLO 6 does not perform an orderly
shutdown when a cautionary temperature level is detected. Disabling this feature does not disable the server hardware from performing
an immediate shutdown when a critical temperature level is detected.
CAUTION:CAUTION: A thermal event can damage server components when the Thermal Shutdown feature is disabled in the
BIOS/Platform Configuration (RBSU).
SubtopicsSubtopics
Fan mode behaviorFan mode behavior
Installing a fanInstalling a fan
Fan mode behaviorFan mode behavior
The seven fan setup provides redundant fan support. In redundant fan mode, if a fan rotor failure occurs:
The system switches to nonredundant fan mode. The system continues to operate in this mode.
The system Health LED flashes amber.
If a second fan rotor failure or a missing fan occurs, the operating system gracefully shuts down.
Installing a fanInstalling a fan
About this taskAbout this task