SFF drive
5. Determine the status of the drive from the drive LED definitions .
6. If removed, install the front bezel .
7. Configure the controller .
ResultsResults
The installation is complete.
Installing a hot-plug LFF SAS, SATA or NVMe drive in box three or box fiveInstalling a hot-plug LFF SAS, SATA or NVMe drive in box three or box five
About this taskAbout this task
CAUTION:CAUTION: To maintain proper system cooling, do not operate the server for long period with the access panel open or
removed. Operating the server in this manner results in an improper system airflow. For internal hot-plug component
procedures, complete the procedure within 60 seconds. Failure to do so can cause the system temperature to increase and
trip the safety threshold. When this happens:
The health LED flashes amber.
The operating system gracefully shuts down.
CAUTION:CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive
devices. To prevent damage, observe antistatic precautions.
CAUTION:CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with
either a component or a blank.