Installing the 2 SFF drive cageInstalling the 2 SFF drive cage
PrerequisitesPrerequisites
Before you perform this procedure, make sure that you have the following items available:
T-10 Torx screwdriver
T-15 Torx screwdriver
ProcedureProcedure
1. If installed, remove the front bezel .
2. Power down the server.
3. If installed, open the cable management arm .
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5. Disconnect all peripheral cables from the server.
6. Remove the server from the rack .
7. Place the server on a flat, level work surface.
8. Remove the access panel .
9. Remove the middle cover .
10. Remove the fans.
11. Remove the fan wall.
12. Remove the universal media bay blank.
Retain the screws and blank. These screws will be used to secure the new 2 SFF side-by-side drive cage assembly.