18. Power up the server .
ResultsResults
The installation is complete.
Chassis intrusion detection switch optionChassis intrusion detection switch option
The chassis intrusion detection switch enables iLO to record an event in the Integrated Management Log (IML) whenever the access panel is
physically opened or removed. An alert is also sent to the BIOS whenever a chassis intrusion is detected. The chassis intrusion detection
occurs as long as the server is plugged in, regardless of whether the server is powered on or off.
SubtopicsSubtopics
Installing the chassis intrusion detection switchInstalling the chassis intrusion detection switch
Installing the chassis intrusion detection switchInstalling the chassis intrusion detection switch
ProcedureProcedure
1. Power down the server.
2. If installed, open the cable management arm .
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack .
6. Place the server on a flat, level work surface.
7. Remove the access panel .
8. Remove the M.2 air baffle .
9. Install the chassis intrusion detection switch:
a. Insert the alignment pins on the middle DIMM guard through the holes on the switch (callout 1).
b. Route the rest of the cable (callout 2).