18. Power up the server .
ResultsResults
The installation is complete.
OCP NIC 3.0 adapter optionOCP NIC 3.0 adapter option
The server supports SFF dual-port and quad-port OCP NIC 3.0 adapter options with various interfaces and advanced interconnect features
for high-bandwidth applications.
SubtopicsSubtopics
Installing the OCP NIC 3.0 adapterInstalling the OCP NIC 3.0 adapter
Installing the OCP NIC 3.0 adapterInstalling the OCP NIC 3.0 adapter
PrerequisitesPrerequisites
Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.
About this taskAbout this task
CAUTION:CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive
devices. To prevent damage, observe antistatic precautions.
CAUTION:CAUTION:
The port blank provides EMI shielding and helps maintain proper thermal status inside the server. Do not operate the server
when a port blank is removed without the corresponding I/O port option installed.
ProcedureProcedure
1. Power down the server.
2. If installed, open the cable management arm .
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack .
6. Place the server on a flat, level work surface.
7. Remove the access panel .
8. Remove the secondary riser cage.
9. Remove the OCP slot blank:
a. Remove the blank screw (callout 1).
b. Remove the blank (callout 2).
Retain the screw and blank for future use.