Sensor Description Remarks
CPU1 VRD Temp CPU VRD temperature CPU1: Component in
position U52 on the
mainboard.
CPU 2: Component in
position U53 on the
mainboard.
N
indicates the CPU ID.
The value is 1 or 2.
CPU
N
MEM Temp CPU DIMM temperature DIMM.
N
indicates the
DIMM ID. The value is 1
or 2.
SYS 3.3V Mainboard 3.3 V voltage Component in position
U21 on the mainboard.
N
indicates the value of
1 or 2.
SYS 5V Mainboard 5.0 V voltage
SYS 12V Mainboard 12.0 V
voltage
CPU
N
VCore 1.8 V CPU voltage
CPU
N
DDR VDDQ 1.2 V DIMM voltage
CPU
N
DDR VDDQ2
RearDisk
N
Temp Rear drive backplane
temperature
Rear drive backplane.
N
indicates the rear drive
backplane number. The
value is 1 or 2.
RAID Temp RAID controller card
temperature
RAID controller card
FAN
N
F Speed or FAN
N
R Speed.
Fan speed Fan module.
N
indicates
the fan module ID. The
value is 1 or 2.
Power Server input power Total PSU power.
Power
N
PSU1 input power PSU.
N
indicates the PSU
ID. The value is 1 or 2.
CPU Usage CPU usage N/A
Memory Usage DIMM usage N/A
CPU
N
Status CPU status check CPU.
N
indicates the CPU
ID. The value is 1 or 2.
CPU
N
Memory DIMM status check DIMM corresponding to
the CPU.
N
indicates the
DIMM ID. The value is 1
or 2.
RH2288H V3 Server
User Guide 11 Appendix
Issue 46 (2022-12-28) Copyright © Huawei Technologies Co., Ltd. 334