Sensor Description Remarks
RTC Battery RTC battery status
An alarm is generated
when the voltage is
lower than 1 V.
CMOS battery
SAS Cable Entity presence Component in position
U46 on the mainboard.
RAID Status RAID controller card
health status
RAID controller card
DIMM
N
DIMM status DIMM.
N
indicates the
DIMM slot number.
PCIE Status PCIe status error N/A
PwrOn TimeOut Power-on timeout N/A
PwrCap Status Power capping status N/A
HDD Backplane Entity presence N/A
HDD BP Status Drive backplane health
status
N/A
Port
N
Link Down Network port link status N/A
AreaIntrusion Unpacking inspection Component in position
S1 on the PSU
backplane.
LCD Status LCD health status LCD
LCD Presence LCD presence status LCD
SD
N
CARD SD card health status SD card.
N
indicates the
SD card ID. The value is
1 or 2.
SSD
N
Temp ES3000 V2 temperature This server model does
not support ES3000 V2.
SSD Disk
N
Temp SSD temperature SSD.
N
indicates the
physical drive slot
number.
No SD Card SD card status N/A
System Notice Hot restart notice
Collect error information
for the fault diagnosis
program.
N/A
RH2288H V3 Server
User Guide 11 Appendix
Issue 46 (2022-12-28) Copyright © Huawei Technologies Co., Ltd. 336