2108 Model G07 Storage Area Network Data Gateway 
 
Dimensions 
Height     89 mm  3.5 in.    
         2 EIA    
Width     425 mm  16.73 in.    
Depth     280 mm  11.0 in.    
Weight 
Minimum     4.1 kg  9.0 lbs.    
Maximum     4.1 kg  9.0 lbs.    
Electrical 
Power source loading 
in active mode 
  
(typical in kVA)  0.2 
Voltage range (V ac)  100 to 127 or 200 to 240 (autoranging) 
Frequency (hertz)  50 or 60 
Thermal output 
(typical)
 
205 Btu/hr 
Power requirements 
(typical) 
60 watts 
Power factor  0.65 120Vac - 0.53 240 Vac 
Maximum altitude  2135 m (7000 ft.) 
Temperature 
Requirements ¹ 
Operating
10 to 40°C
(50 to 104°F)
 
Non-Operating
10 to 43°C
(50 to 110°F)
 
Humidity 
Requirements
 
Operating  Non-Operating 
(Noncondensing)  8 to 80%  8 to 80% 
Wet Bulb  23°C (73°F)  27°C (80°F) 
Noise Emissions ²  Operating  Idle 
L
WAd 
6.2 bels  N/A bels 
L
pAm 
N/A  N/A 
<L
pA
>
m 
45 dBA  N/A dBA 
Impulsive or 
prominent discrete 
tones
 
No  No 
Install/Air Flow.  When mounted in an enclosed rack, provision must be made to allow for a minimum of 24 
cubic feet per minute of air flow to the exterior of the rack. 
1.    The recommended operating temperature is 22°C (72°F) or lower. 
2.    See “Noise Emission Notes” on page 336 for definitions of noise emissions positions.
 
 
 
 
Chapter 5. Physical Characteristics of the 2100 Series  241