7010 Xstation 140 and 150 
 
Dimensions 
Height     72 mm  2.9 in.    
Width     375 mm  14.8 in.    
Depth     380 mm  15.0 in.    
Weight 
Minimum     7.3 kg  16 lbs.    
Maximum     8.6 kg  19 lbs.    
Electrical 
Power source loading 
(maximum in kVA)
 
0.100 
Voltage range (V ac)  100 to 125 or 200 to 240 (autoranging) 
Frequency (hertz)  50 or 60 
Thermal output (max)  222 Btu/hr 
Power requirements 
(peak) 
65 watts 
Power factor  0.5 to 0.7 
Maximum altitude  2135 m (7000 ft.) 
Temperature 
Requirements 
Operating
16 to 32°C
(60 to 90°F)
 
Non-Operating
10 to 43°C
(50 to 110°F)
 
Humidity 
Requirements 
Operating  Non-Operating 
(Noncondensing)  8 to 80%  8 to 80% 
Wet Bulb  23°C (73°F)  27°C (80°F) 
Noise Emissions¹  Operating  Idle 
L
WAd 
4.7 bels  4.7 bels 
L
pAm 
33 dBA  33 dBA 
<L
pA
>
m 
31 dBA  31 dBA 
Impulsive or 
prominent discrete 
tones
 
No  No 
Clearances  Front  Back  Left  Right 
Install/Air Flow²  152 mm(6 in)  152 mm(6 in)  N/A  N/A 
Footprint²  Width
375 mm(14.8 in) 
Depth
685 mm(27 in) 
1.    See “Noise Emission Notes” on page 336 for definitions of noise emissions positions. 
2.    The amount of space needed by the unit during normal operation is indicated by the footprint dimensions.
 
 
 
 
14  Site and Hardware Planning Information