7010 Xstation Model 160 
 
Dimensions 
Height     68 mm  2.75 in.    
Width     306 mm  12.00 in.    
Depth     306 mm  12.00 in.    
Weight 
Minimum     4.1 kg  10 lbs.    
Maximum     4.5 kg  9 lbs.    
Electrical 
Power source loading 
(maximum in kVA)
 
0.121 
Voltage range (V ac)  100 to 125 or 200 to 240 (autoranging) 
Frequency (hertz)  50 or 60 
Thermal output (max)  143 Btu/hr 
Power requirements 
(peak) 
50 watts 
Power factor  0.715 
Maximum altitude  2135 m (7000 ft.) 
Temperature 
Requirements 
Operating
16 to 32°C
(60 to 90°F)
 
Non-Operating
10 to 43°C
(50 to 110°F)
 
Humidity 
Requirements 
Operating  Non-Operating 
(Noncondensing)  8 to 80%  8 to 80% 
Wet Bulb  23°C (73°F)  27°C (80°F) 
Noise Emissions¹  Operating  Idle 
L
WAd 
4.3 bels  4.3 bels 
L
pAm 
37 dBA  37 dBA 
<L
pA
>
m 
41 dBA  41 dBA 
Impulsive or 
prominent discrete 
tones
 
No  No 
Clearances  Front  Back  Left  Right 
Install/Air Flow²  152 mm(6 in)  152 mm(6 in)  152 mm(6 in)  152 mm(6 in) 
Footprint²  Width
612 mm(24 in) 
Depth
612 mm(24 in) 
1.    See “Noise Emission Notes” on page 336 for definitions of noise emissions positions. 
2.    The amount of space needed by the unit during normal operation is indicated by the footprint dimensions.
 
 
 
 
Chapter 2. Physical Characteristics of Systems  15