TR3101
Cognos Transformer could not create the directory directory_name.
You may have insufficient space in your temp directory or on the drive where the
temp directory resides.
Procedure
To resolve the problem, try the following:
v Free up some disk space.
v Check the size of, and available space for, free conventional memory and the
swap file.
v Run disk scan and defragmentation utilities on the Cognos Transformer
computer, to ensure that the free hard drive space is contiguous.
TR3124
The root user class identifier in the model file was not found in the namespace.
Ensure that you have selected the Series 7 namespace that corresponds to the
model file.
You are upgrading a model containing user class views that was created using
Cognos Transformer version 7.x. The current security namespace is not the same
Access Manager namespace that the IBM Cognos Series 7 model was designed
with.
Procedure
In IBM Cognos, use the Series 7 namespace that you used to create the IBM
Cognos Series 7 user class views.
TR3311
An error occurred during data retrieval from the database. If available, refer to the
Details for more information.
You may get this error message when you try to create a PowerCube using an .iqd
file that accesses an Oracle data source. If the error only occurs during periods of
peak network traffic, the problem may be that the expire_time parameter has been
changed from its default setting (zero) in the sqlnet.ora file.
Procedure
If you suspect that a default setting is at fault, please contact your database
administrator.
TR3519
This calculated category definition is not valid.
The calculation expression you have defined for your calculated column is invalid
because it does not follow the right syntax rules.
310 IBM Cognos Transformer Version 10.1.1: User Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Cognos and is the answer not in the manual?

IBM Cognos Specifications

General IconGeneral
DeveloperIBM
Data Sourceflat files
Operating SystemMicrosoft Windows
LicenseCommercial
Input SourcesSQL databases, Excel, CSV
PlatformMicrosoft Windows