r--
I 
---.-------------------------------T-------' 
I 
Code 
ICause 
IRestart 
IRef.No.1 
I  ESTR  ,  I  I  I 
l------+ 
I 
+-------1 
I 
OD01 
IThe 
input. 
data 
file 
read 
on 
the 
2501 
I  55  I 
I 
,contains 
a 
record 
which, 
according 
to 
,  I 
lithe 
input. 
specifications, 
is 
incorrect 
I  I 
I 
lor 
out 
of 
sequence. 
I  I 
r------+--------
-f 
I 
I 
OD02 
IThe 
input 
data 
file 
read 
on 
the 
2560 
I  I 
I 
Iprimary 
feed 
contains 
a 
record 
which, 
I  , 
I 
,according 
to 
the 
input 
specifications, 
I  , 
, 
lis 
incorrect 
or 
out 
of 
sequence. 
,  I 
r---+---------------------------------I 
, 
I 
OD03 
IThe 
input 
data 
file 
read 
on 
the 
256C  ,  , 
I 
,secondary 
feed 
contains 
a 
record 
which, 
I  I 
, 
laccording 
to 
the 
input 
specifications, 
I  I 
I 
lis 
incorrect 
or 
out 
of 
sequence. 
I  , 
j----+ 
--+ 
+--------1 
J 
OD07 
IThe 
input 
data 
file 
read 
on 
a 
2415 
tape 
IOperator 
choice: 
I  57  , 
I 
Idrive 
contains 
a 
record 
which, 
accordingla} 
Press 
START 
on 
CPU 
to 
I  I 
I 
Ito 
the 
input 
specifications, 
is 
I 
discontinue 
the 
jot. 
I  I 
I  I 
incorrect 
or 
out 
of 
sequence. 
11:) 
Enter 
FF 
into 
loca 
tion 
CE 
I  I 
I  I  I 
and 
press 
STARr 
on 
CPU 
to 
I  I 
I  ,  I 
continue 
processing 
I  , 
1------+ 
-+-
, 
-I 
I 
ODOF 
IUser-programmed 
halt 
provided 
by 
means 
IOFerator 
choice: 
I  53  , 
I 
lof 
halt 
indicator 
H2.  .  I a) 
Press 
START 
on 
CPU 
to 
I  I 
I  I  I 
continue 
the 
jot. 
I  I 
I  I  I b) 
Enter 
FF 
into 
loca 
tion 
CE 
I  I 
I  I  I 
and 
press 
ST 
ART 
on 
CPU 
to 
I  I 
I  I  I 
discontinue 
the 
job. 
,  , 
r------+---------------------------------+ 
--+--------1 
I 
OD10 
,Input 
of 
tables 
is 
completed. 
IPress 
STABT 
on 
CPU 
to 
I  I 
~~--------------------------------------~continue 
processing. 
'I 
I 
OD11 
I 
Data 
processing 
is 
completed 
and 
I  ,  I 
I  I 
outpu 
t 
of 
tables 
is 
to 
follow., 
,  , 
~ 
I 
-+--------------------------+-------1 
I 
OD12 
IThe 
number 
of 
tatle 
recerds 
read 
from 
a 
IPress 
START 
on 
CPU 
to 
I  53  I 
I 
Icard 
reading 
device 
is 
lower 
than 
the 
,discontinue 
the 
jot. 
" 
I  I 
number 
specified 
in 
the 
source 
program. 
I  I  I 
1-------+ 
-I 
I  , 
, 
OD13 
IThe 
number 
of 
table 
records 
read 
from 
,  ,  , 
, 
la 
tape 
drive 
is 
lower 
than 
the 
number 
I  I  , 
,  I 
specified 
in 
th 
e 
sour 
ce 
pro 
gr 
am.  ,  I  I 
~ 
I 
+--------------------------+------1 
, 
OD14 
IA 
reflective 
marker 
has 
teen 
encountered, 
I  53  I 
I  I 
while 
a 
table 
is 
being 
written 
on 
tape. 
I  I  I 
1---
, 
+------------------------------+-----1 
OD21 
12501 
End-of-file 
condition 
,OFerator 
choice: 
I  I 
OD22 
12560,2520 
occurred, 
but 
one 
or 
more 
,a) 
Fress 
STABT 
on 
CPU 
to 
,53, 
OD23 
11442 
records 
required 
according 
, 
discontinue 
the 
jot. 
,  I 
OD27 
12415 
to 
sequence 
specifications 
Ib} 
Enter 
FF 
into 
location 
CE, 
I 
I 
have 
not 
been 
read. 
,and 
press 
START 
on 
CPU 
to, 
I 
,  , 
centinue 
processing 
with 
I  I 
I  I 
end-of-
file 
condi 
tion. 
,  I 
I 
'c) 
For 
stop 
no. 
0])21, 
OI22" 
I 
I  , 
OI23, 
continuation 
of 
the 
I  I 
,  , 
jeb 
is 
possitle 
as 
indicatedl 
I 
,  , 
under 
Restart 
55, 
provided 
a, 
, 
I  I 
value 
other 
than 
FF 
or 
00 
isl 
I 
I  I 
entered 
into 
location 
CE., 
I 
t------+---------------------------------+---------------------------+------1 
I 
OD30 
,Error 
statistics 
are 
not 
specified 
in 
,Press 
STABT 
on 
CPU 
to 
I  53  I 
I  I 
column 
35 
of 
the 
RPG 
control 
card, 
but 
,discontinue 
the 
jol::. 
'I 
I 
Ian 
OPTN 
TES 
card 
is 
present. 
I  I  I 
L---
, 
~ 
___________________________ 
~ 
_______ 
J 
140 
System/360 
Model 
20 
TPS 
Operating 
Procedures