r-
I
------------------~i-----------
1-'
I
Code
ICause
IRestart
IRef.No.1
I ESTR I I I I
~
I
-------------+1--
+------4
I
1B33
ITape
mark
has
been
read
on
SYSIPT.
IOperator
choice:
I I
I I I a)
Press
START
on
CPU
to
I I
I I I
continue
processing
with
I I
I I I
same
reel.
I I
I I
I b)
Mount
new
reel
and
press
I I
I I I START
on
CPU
to
continue
I I
I I I
processing.
I I
1--- I
-+
I
-f
1
1B34.
IInput
records
are
out
of
sequence.
IPress
STABT
on
CPU
to
I
53
I
I I 1
discontinue
the
job.
I I
I
t
--1B35
II
First
card
column
contains
charact~r
~press
STABT
on
CPU
to
cont-i-n-u-e~:--
1
other
than
blank
or
12-2-9,
or
--
1f
I
'I
I
processing.
(The
card
is
I I
I I
blank
--
card
is
not
a PHASE, ACTION,
lignored.)
I I
1-__
I
or
ENTRY
card.
I
+---
__
~
I 1B36 IREP
card
contains
an
incorrect
I
Press
START
on
CPU
to
53
I
Ispecification.
Idiscontinue
the
job.
1--- I
-I
I
1837
ILoad
address
calculated
from
PHASE
I
II
Istatement
is
higher
than
32,767.
I
t-----t
-I
I
1B38
11st
input
statement
is
not
a PHASE I
I I
statement.
I
I-
+---
-----------------1
I
1B39
INo
TXT
cards
present
for
last
phase.
I
l-
I
~
I
1B40
lEnd
of
reel
reached
on
SYSOOO
or
I
I ISYSOPT. I
~
I +
---+-----1
I 1B41
lOuring
read
operation,
tape
mark
IPress
START
on
CPU
to
58
53
I
I
I
lencountered
where
not
expected,
or
I
discontinue
the
job.
I
Irecord
of
incorrect
length
read.
I
I
I-
+_
I
I
1B42
ITape
on
SYSOOO
is
mispositioned.
I
Press
STABT
on
CPU
to
-t------t
I
53
I
I I
(Hardware
malfunction.)
I
discontin
ue
the
job.
I I
)----+
-I
I
1B43
IThe
same
tape
drive
assigned
to
more
I
Ithan
one
symbolic
device
address
used,
1
lor
no
device
assigned
to
required
I
Isymbolic
device
address,
or
"data
I
Iconverter
off"
specified
for
7-track
I
Itape
drive.
)----+-
I
1B44
IName
field
of
control
statement
contains
I
lincorrect
specification,
or,
if
SYSIPT
I
land
SYSRDR
refer
to
the
same
device,
I IPHASE
statement
is
not
preceded
by a
I
Icontrol
statement.
~
I ,
I
1B45
IControl
statement
contains
invalid
I
I
loperation
code.
I
~
I
----------------1
I
1B46
11st
operand
or
separator
(,)
or
I
I I
delimiter
(blank)
of
control
I
I I
statement
is
incorrect.
I
1----+
~
I
1B47
12nd
operand
or
separator
(,)
of
control
I
I
Istatement
is
incorrect.
I
I-----+-
-t
I "IB48
13rd
operand
or
separator
(,)
or
deli-
I
I I
miter
(blank)
is
incorrect.
I
1-----+
~
I
1B49
14th
operand
or
delimiter
(blank)
is
I
I
Ii
ncorrect.
I
L
___
---'-
148
System/360
Model
20
TPS
Operating
Procedures
I I
I I
I I
I I
I I
I I
I I
+----1
Follow
procedure
52
and
correctl
52
or
insert
the
control
statementl
before
returning
the
hopper
I
deck
to
the
hopper.
I
I
I
I
I
I
I
J

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System/360 20 and is the answer not in the manual?

IBM System/360 20 Specifications

General IconGeneral
BrandIBM
ModelSystem/360 20
CategoryStorage
LanguageEnglish

Related product manuals