Page #98 background imageLoading...
Page #98 background image
in
the
DTFSR
statement
~tatement
num-
ber
20
in
Figure
36)
the
data
cards
and
the
end-af-file
card.
6.
For
the
master
program:
Press
the
Start
key
on
the
card
reader.
for
the
slave
program:
Press
the
Start
key
on
the
card
punch.
7.
Press
the
Reset
key
and
the
Start
key
on
the
printer.
8.
Press
the
Load
key
on
the
CPU
console.
The
slave
program
should,
if
possible,
be
loaded
just
before
the
master
program.
If
the
master
program
is
loaded
before
the
slave,
the
slave
must
be
loaded
within
the
next
three
minutes,
otherwise
there
will
be
a
halt
with
E-S-T-R
display
0553
on
the
console
of
the
master
cpu.
If
this
hap-
pens,
the
master
program
must
be
loaded
again.
After
all
the
data
cards
have
been
read
and
transmitted,
a
programmed
halt
occurs
and
code
OF10
is
displayed
on
the
consoles
of
both
the
master
and
the
slave
CPUs.
MANUAL
INTERVENTION (SLAVE
TERMINAL
ONLY)
If
the
operator
at
the
slave
terminal
wishes
to
suspend
operation,
he
must:
1.
Set
the
Register-Data/Address
switches
on
the
cpu
console
to
the
address
of
the
SAK
byte.
This
address
is
obtained
from
the
assembly
listing
of
the
slave
program.
2.
Set
the
Data
switch
to
a
value
other
th'an
zero.
3.
Set
the
~ode
switch
to
STCB
ALTER.
4.
Press
the
Start
key
on
the
CEU
console
to
set
the
SAK
byte
to
the
value
indi-
cated
by
the
tata
switch.
5.
Set
the
Mode
switch
to
PROCESS.
6.
Press
the
Start
~ey
on
the
CEU
console.
This
will
cause
a
halt,
with
E-S-T-R
disflay
OF20
on
the
cOI.sole
at
the
slave
terminal
and
OF30
on
the
console
at
the
master
terminal.
To
resume
operation,
the
operator
at
the
slave
terminal
must
press
the
start
key
on
the
CPU
console.
When
the
operator
at
the
master
terminal
receives
the
OF30
display,
he
should
com-
municate
with
the
operator
at
the
slave
terminal,
or
wait
a
prearranged
time
and
then
press
START
on
his
console
to
resume
operation.
HALTS
AND
ERROR
DISPLAYS
In
addition
to
the
standard
BSCA
IOCS
halts,
there
are
a
number
of
other
halts
that
may
occur
during
execution
of
the
master
and
slave
sample
programs.
These
halts,
together
with
the
restart
procedures
are
shown
in
Figure
40.
98
system/360
Model
20 TPS