IDEC SmartRelay functions
118
IDEC SmartRelay Manual
Parameter preset = Actual value of an already programmed func-
tion
How to include the actual value of an actual value of an al-
ready programmed function:
1. Press to move the cursor to the equal sign of param-
eter T.
2. Press to change the equal sign into an arrow. If it ex-
ists, the last referenced block and its timebase is shown.
3. Press to move the cursor to the “B” of the shown
block, and then press to select the required block
number.
4. Press to move the cursor to the block’s timebase and
press to select the required timebase.
The view in parameter assignment mode (example):
T =04:10h
B12 +R
T =04:10h
B12 +R B12 +RB12 +R
T =04:10h
T =04:10h
Press
twice
B12 +R
T B006s
B12 +R
T B006m
T =04:10hT =04:10
Ta =02:00h
B12B12
T B006m
Ta =02:00h
or
current
time