Parameter Groups
182
Min.:
0
Unit:
Max.: 0x111 Data type: UInt16
Default:
0
Change: In real time
Value Range:
Ones (position): AI1
0: Percentage corresponding to minimum input
1: 0.0%
Tens (position): AI2
0: Percentage corresponding to minimum input
1: 0.0%
Hundreds (position): AI3
0: Percentage corresponding to minimum input
1: 0.0%
Description
The settings for AI1 to AI3 less than minimum input are set through the ones, tens,
and hundreds positions of this parameter. When the analog input voltage is less
than the minimum input set by F4‑13, the corresponding setting value is
calculated according to the minimum input or 0.0% defined by this parameter.
F4-35
DI1 delay
Address:
0xF423
Min.:
0
Unit:
s
Max.: 3600 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.0s to 3600.0s
Description
This parameter defines the delay of the DI state change. The delay setting
function is available only for DI1, DI2, and DI3 currently.
F4-36
DI2 delay
Address:
0xF424
Min.:
0
Unit:
s
Max.: 3600 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.0s to 3600.0s
Description
This parameter defines the delay of the DI state change. The delay setting
function is available only for DI1, DI2, and DI3 currently.