Parameter Groups
214
F6-21
Demagnetization time
Address:
0xF615
Min.:
0
Unit:
s
Max.: 10 Data type: UInt16
Default:
1
Change: In real time
Value Range:
0.00s to 10.00s
Description
In the vector mode, when flying start is enabled (F6‑00 = 1), the AC drive cannot be
started when the motor has residual magnetism. The AC drive can only be started
after the voltage output of the AC drive is disconnected for at least the
demagnetization time set by F6‑21.
F6-22
Startup pre-torque setting
Address:
0xF616
Min.:
0
Unit:
%
Max.: 200 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.0% to 200.0%
Description
F6-26
Electromagnetic shorting current
Address:
0xF61A
Min.:
0
Unit:
%
Max.: 200 Data type: UInt16
Default:
100
Change: In real time
Value Range:
0% to 200%
Description
F6-27
Electromagnetic shorting time upon startup
Address:
0xF61B
Min.:
0
Unit:
s
Max.: 100 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0.0s to 100.0s
Description