Parameter Groups
‑221‑
F7-07
Inverter heatsink temperature
Address:
0xF707
Min.:
‑20
Unit: °C
Max.: 120 Data type: Int16
Default:
0
Change: Unchangeable
Value Range:
‑20℃ to +120℃
Description
Indicates the inverter heatsink temperature.
F7-08
Product No.
Address:
0xF708
Min.:
0
Unit:
Max.: 999 Data type: UInt16
Default:
0
Change: Unchangeable
Value Range:
0999
Description
This parameter shows the product No. of the AC drive.
F7-09
Accumulative running time
Address:
0xF709
Min.:
0
Unit:
h
Max.: 65535 Data type: UInt16
Default:
0
Change: Unchangeable
Value Range:
0 h to 65535 h
Description
This parameter shows the accumulative running time of the AC drive.
F7-10
Performance software version
Address:
0xF70A
Min.:
0
Unit:
Max.: 0 Data type: UInt16
Default:
0
Change: Unchangeable
Value Range:
0.00 to 0.00
Description
Indicates the performance software version of the AC drive.
F7-11
Function software version
Address:
0xF70B