Parameter Groups
230
Description
Frequency detection hysteresis (FDT1) = F8‑19 x F8‑20 When the running
frequency is higher than F8‑19, the DO outputs an active signal. When the running
frequency is lower than a specific value (F8‑19 F8‑19 x F8‑20), the DO outputs an
inactive signal.
F8-21
Detection width for frequency reach
Address:
0xF815
Min.:
0
Unit:
%
Max.: 100 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.0% to 100.0%
Description
Detection width for frequency reach = F8‑21 (Detection width of frequency reach)
x F0‑10 (Maximum frequency) The DO outputs an active signal when the running
frequency of the AC drive is in the specific range (Frequency reference ± F0‑10 x
F8‑21).
F8-22
Jump frequency state during acceleration/deceleration
Address:
0xF816
Min.:
0
Unit:
Max.: 1 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0: Inactive
1: Active
Description
Used to enable or disable the jump frequency function during acceleration/
deceleration.
0: Inactive
During acceleration and deceleration, if the running frequency reaches the jump
frequency boundary, the AC drive will continue to run at the running frequency.
1: Active
During acceleration or deceleration, upon the moment that the running frequency
reaches the jump frequency, the AC drive will jump over the jump frequency with
the amplitude twice the value of F8‑11 (jump frequency amplitude).
F8-25
Switchover frequency of acceleration time 1 and acceleration time 2
Address:
0xF819
Min.:
0
Unit:
Hz