Parameter Groups
280
Description
It is the percentage of triangular wave rising time to FB‑03 (Wobble cycle).
FB-05
Set length
Address:
0xFB05
Min.:
0
Unit:
m
Max.: 65535 Data type: UInt16
Default:
1000
Change: In real time
Value Range:
0 m to 65535 m
Description
This parameter specifies the length value to be controlled in fixed length control
mode.
FB-06
Actual length
Address:
0xFB06
Min.:
0
Unit:
m
Max.: 65535 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0 m to 65535 m
Description
The actual length is a monitored value. Actual length (FB‑06) = Number of pulses
sampled by terminal/Number of pulses each meter (FB‑07)
FB-07
Number of pulses per meter
Address:
0xFB07
Min.:
0.1
Unit:
Max.: 6553.5 Data type: UInt16
Default:
100
Change: In real time
Value Range:
0.16553.5
Description
Indicates the number of pulses output per 1 m. The length pulse is sampled by
DI5. DI5 must be allocated with the length count input function (F4‑04 = 27).
FB-08
Set count value
Address:
0xFB08
Min.:
1
Unit:
Max.: 65535 Data type: UInt16
Default:
1000
Change: In real time