Parameter Groups
‑358‑
Default:
10
Change: In real time
Value Range:
A6‑04 to 10.00 V
Description
This parameter defines the x axis of the maximum input point on AI curve 4, that
is, the maximum analog input voltage or current.
A6-07
Percentage corresponding to curve 4 maximum input
Address:
0xA607
Min.:
‑100
Unit:
%
Max.: 100 Data type: Int16
Default:
100
Change: In real time
Value Range:
‑100.0% to +100.0%
Description
This parameter defines the y axis of the maximum input point on AI curve 4, that
is, the setting value that the AI maximum input corresponds.
A6-08
Curve 5 minimum input
Address:
0xA608
Min.:
‑10
Unit:
V
Max.: A6‑10 Data type: Int16
Default:
‑10
Change: In real time
Value Range:
‑10.00 V to A6‑10
Description
This parameter defines the x axis of the minimum input on AI curve 5, that is, the
minimum analog input voltage or current.
A6-09
Percentage corresponding to curve 5 minimum input
Address:
0xA609
Min.:
‑100
Unit:
%
Max.: 100 Data type: Int16
Default:
‑100
Change: In real time
Value Range:
‑100.0% to +100.0%
Description
This parameter defines the y axis of the minimum input point on AI curve 5, that
is, the setting value that the AI minimum input corresponds.