Parameter Groups
‑390‑
Description
When PT100 analog voltage correction is carried out on AI3, a correction curve is
formed through two points. Each point corresponds to a measured voltage and a
displayed voltage. The measured voltage is the voltage measured using a meter,
and the displayed voltage is the PTC voltage before correction (U0‑47).
AC-24
PT1000 measured voltage 1
Address:
0xAC18
Min.:
0
Unit:
V
Max.: 3.3 Data type: Int16
Default:
0.44
Change: In real time
Value Range:
0.000 V to 3.3 V
Description
When PT1000 analog voltage correction is carried out on AI3, a correction curve is
formed through two points. Each point corresponds to a measured voltage and a
displayed voltage. The measured voltage is the voltage measured using a meter,
and the displayed voltage is the PTC voltage before correction (U0‑47).
AC-25
Voltage 1 display on the PT1000
Address:
0xAC19
Min.:
0
Unit:
V
Max.: 3.3 Data type: Int16
Default:
0.44
Change: In real time
Value Range:
0.000 V to 3.3 V
Description
When PT1000 analog voltage correction is carried out on AI3, a correction curve is
formed through two points. Each point corresponds to a measured voltage and a
displayed voltage. The measured voltage is the voltage measured using a meter,
and the displayed voltage is the PTC voltage before correction (U0‑47).
AC-26
PT1000 measured voltage 2
Address:
0xAC1A
Min.:
0
Unit:
V
Max.: 3.3 Data type: Int16
Default:
2.16
Change: In real time
Value Range:
0.000 V to 3.3 V