Parameter Groups
414
B0-12
Initial roll diameter 2
Address:
0xB00C
Min.:
0.1
Unit:
mm
Max.: 6000 Data type: UInt16
Default:
100
Change: In real time
Value Range:
0.1 mm to 6000.0 mm
Description
For details about initial roll diameters 1 to 3, see B0‑10.
B0-13
Initial roll diameter 3
Address:
0xB00D
Min.:
0.1
Unit:
mm
Max.: 6000 Data type: UInt16
Default:
100
Change: In real time
Value Range:
0.1 mm to 6000.0 mm
Description
For details about initial roll diameters 1 to 3, see B0‑10.
B0-14
Current roll diameter
Address:
0xB00E
Min.:
0.1
Unit:
mm
Max.: 6000 Data type: UInt16
Default:
100
Change: In real time
Value Range:
0.1 mm to 6000.0 mm
Description
This parameter shows the current roll diameter in real time. Modifying this
parameter can modify the current roll diameter, and the result of roll diameter
calculation will override this parameter (except B0‑07 = 7). It can also be used as a
way to reset the roll diameter.
B0-15
Roll diameter filter time
Address:
0xB00F
Min.:
0
Unit:
s
Max.: 10 Data type: UInt16
Default:
5
Change: In real time
Value Range:
0.00s to 10.00s
Description