This parameter takes effect only when B0‑07 is set to 0.
You can set B0‑15 to filter roll diameter calculation results and suppress roll
diameter jitter. A larger value of B0‑15 means smoother calculated roll diameter
and longer delay in roll diameter changes. Rule: When the roll diameter changes
linearly, the time that the calculated roll diameter lags behind the actual roll
diameter is basically equal to this parameter value.
B0-16
Winding diameter change rate
Address:
0xB010
Min.:
0
Unit:
‑
Max.: 1000 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.0–1000.0
Description
This parameter takes effect only when B0‑07 is set to 0.
You can set B0‑16 to a non‑zero value to limit the change of roll diameter per unit
of time and prevent abnormal fast change. An excessively low roll diameter
change rate may result in large delay in roll diameter calculation. Set the change
rate properly based on the actual conditions, for example, based on the
maximum change rate corresponding to the linear speed of 100.0 m/min.
B0-17
Roll diameter change direction limit
Address:
0xB011
Min.:
0
Unit:
‑
Max.: 1 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0: Disabled
1: Decrease disabled during winding, and increase disabled during unwinding
Description
This parameter takes effect only when B0‑07 is set to 0.
Set this parameter to limit the direction change of the roll diameter. Use it under
the condition of setting B0‑16 reasonably. Otherwise, if there is abnormal
fluctuation of roll diameter, excessive deviation of winding diameter calculation
result will be caused.
B0-18
Roll diameter reset during running
Address:
0xB012
Min.:
0
Unit:
‑
Max.: 1 Data type: UInt16