Parameter Groups
‑416‑
Default:
0
Change: In real time
Value Range:
0–1
Description
This parameter can be used to enable roll diameter reset during operation.
B0-19
Pre-drive speed gain
Address:
0xB013
Min.:
‑100
Unit:
%
Max.: 200 Data type: Int16
Default:
0
Change: In real time
Value Range:
‑100.0% to +200.0%
Description
For pre‑drive, the running frequency is automatically calculated based on the
linear speed and roll diameter to ensure matching with the linear speed of the
material. For small deviation of linear speed, set B0‑19 to increase or decrease the
running frequency during pre‑drive, ensuring accurate linear speed matching.
B0-20
Pre-drive torque limit source
Address:
0xB014
Min.:
0
Unit:
‑
Max.: 1 Data type: UInt16
Default:
1
Change:
At stop
Value Range:
0: Set by F2‑09
1: Set based on tension control torque
Description
In the torque control tension mode, the target torque is automatically generated
to meet the material tension demand. In the normal operation mode, the target
torque can also be set according to the channel selected by F2‑09. This parameter
provides the preceding options for the source of the target torque in the pre‑drive
mode. You can set it as required. 0: The target torque is set by the channel
selected by F2‑09. 1: The target torque is set according to the tension control
open‑loop torque (for mode 1 and mode 3 only).
B0-21
Pre-drive torque correction
Address:
0xB015
Min.:
‑100
Unit:
%
Max.: 100 Data type: Int16
Default:
0
Change: In real time