Goodrive300-01A-RT series integrated machine Commissioning instruction
-19-
If you select SM (synchronous motor), you need to set the max frequency, rated frequency,
rated power, rated voltage, rated current, pole pairs, and carrier frequency.
If you select AM (asynchronous motor), you need to set the max frequency, rated frequency,
rated power, rated voltage, rated current, rated rotational speed, and carrier frequency.
Figure 4-6 Main motor parameter setting interface
Set motor parameters according to the actual motor nameplate parameters, click Para autotune.
Step 2 On the system configuration interface, click Set up Parameters. The VFD completes the
related parameter configuration automatically. See appendix C.6 for setting parameters.
Step 3 On the system configuration interface, click Debug mode.
Figure 4-7 Debug mode interface