iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual Issue 2.5
148
Table 4.3.5.7-1 CO Additional Attributes (PGM 148)
BTN
ATTRIBUTE/DISPLAY
DESCRIPTION
RANGE
DEFAULT
9
01-02 CC BLOCKING
(0-2): DISABLED
It’s for only Brazil R2. It blocks for a
collect call if a double answer or
with indication is selected.
0: Disabled, 1: Double Answer,
2: With Indicator
Refer to
description
Disabled
10
01-02 CC ANS TMR
(001-250): 010 (100ms)
If it is set to Double Answer for
collect call blocking, this timer is
sending a dummy answer signal.
1-250
(100ms)
10
11
01-02 CC IDLE TMR
(001-250): 020 (100ms)
If it is set to Double Answer for
collect call blocking, this timer is
sending a dummy idle signal.
1-250
(100ms)
20
12
01-02 LINE MONITORING
(1: ON / 0: OFF): ON
This determines that detect line
fault or not.
0: OFF
1: ON
ON
13
01-02 RING DETECT REG
(000-255): 015
In the web admin, it is located in the
Maintenance page [Appliances
Control] > [Analog CO Parameter
Set].
000-255
015