Table 34: Component LEDs on the Services Gateway (continued)
Possible Causes and
Corrective ActionsMeaningStateLED
Normal condition. No action
is required.
Indicates that the device is
functioning normally.
GreenPower LED
Normal condition. No action
is required.
Indicates that the Power
button has been pressed and
quickly released and the
device is gracefully shutting
down.
Amber
Normal condition if the
services gateway is
switched-off. No action is
required.
If you have not powered off
the services gateway, verify
that the AC power cord
from the power source to
the device is not damaged,
the socket is in working
condition, and the device
has an AC input voltage
between 100 and 240 VAC.
See “Monitoring the
SRX100 Services Gateway
Power System” on page 101.
Off indicates that the device
is not receiving power.
Off
Related
Documentation
Monitoring the SRX100 Services Gateway Chassis Using the CLI on page 95
Monitoring the SRX100 Services Gateway Using Chassis Alarm Conditions on page 99
Monitoring the SRX100 Services Gateway Power System on page 101
Using the Reset Config Button on the SRX100 Services Gateway on page 102
Changing the Reset Config Button Behavior on the SRX100 Services Gateway on
page 103
Juniper Networks Technical Assistance Center on page 103
Monitoring the SRX100 Services Gateway Using Chassis Alarm Conditions
When the services gateway detects an alarm condition, the alarm LED on the front panel
turns red or amber as appropriate.
To view a more detailed description of the alarm cause, issue the show chassis alarms
CLI command.
For more information on the show chassis alarms command, see the following topics:
Initial Configuration for Security Devices
99Copyright © 2015, Juniper Networks, Inc.
Chapter 16: Troubleshooting Components

Table of Contents

Other manuals for Juniper SRX100B

Related product manuals