NOTE: If the system is completely powered off when you turn on the power
supply, the devicestarts as the powersupplycompletesits startup sequence.
If the device finishes starting and you need to power off the system again,
first issue the CLI request system power-off command.
Powering Off the SRX100 Services Gateway
You can power off the services gateway in one of the following ways:
•
Graceful shutdown—Press and immediately release the Power button. The device
begins gracefully shutting down the operating system and then powers itself off.
WARNING: Use the graceful shutdown method to power off or reboot the
services gateway.
•
Forced shutdown—Press the Power button and hold it for ten seconds. The device
immediately powers itself off without shutting down the operating system.
WARNING: Use the forced shutdown method as a last resort to recover
the services gateway if the services gateway operating system is not
responding to the graceful shutdown method.
For more information on power button, see “SRX100 Services Gateway LEDs” on page 7.
WARNING: Do not press the Power button whilethe device is shutting down.
CAUTION: Forced shutdown can result in data loss and corruption of the file
system.
NOTE: To remove power completely from the device, unplug the power cord
or switch off the AC power source.
After powering off a power supply, wait at least 10 seconds before turning it
back on. After powering on a power supply, wait at least 10 seconds before
turning it off.
The power button on the services gateway is a standby power switch, which
will not turn off the input power to the services gateway.
67Copyright © 2015, Juniper Networks, Inc.
Chapter 13: Providing Power to the SRX100 Services Gateway