Table 24: SRX100 Services Gateway Grounding Components
ComponentNumber
Grounding point on the chassis1
Grounding lug2
Grounding screw (M3 screw)3
Table 25 on page 58 lists the specifications of the grounding cable used with the device.
Table 25: Grounding Cable Specifications for the Services Gateway
SpecificationGrounding Requirement
14 AWG single-strand wire cableGrounding cable
Up to 4 AAmperage of grounding cable
Ring-type, vinyl-insulated TV14-6R lug or
equivalent
Grounding lug
To ground the device:
1. Connect the grounding cable to a proper earth ground.
2. Verify that a licensed electrician has attached the cable lug to the grounding cable.
3. Place the grounding cable lug over the grounding point on the middle rear of the
chassis.
4. Secure the grounding cable lug to the grounding point with the screw as shown in
Figure 13 on page 57.
5. Dress the grounding cable and verify that it does not touch or block access to the
services gateway components and that it does not drape where people could trip on
it.
NOTE: The device should be permanently connected to ground during
operation.
Related
Documentation
Connecting the SRX100 Services Gateway to the Power Supply on page 65
Connecting and Organizing Interface Cables to the SRX100 Services Gateway on
page 61
SRX100 Services Gateway General Safety Guidelines and Warnings on page 117
Powering On and Powering Off the SRX100 Services Gateway on page 66
Using the Reset Config Button on the SRX100 Services Gateway on page 102
Copyright © 2015, Juniper Networks, Inc.58
SRX100 Services Gateway Hardware Guide for B and H Model Numbers

Table of Contents

Other manuals for Juniper SRX100B

Related product manuals