Parameter Descriptions
140
© 2024 KEB America, Inc.
LS22 Acceleration Jerk High Speed
Acceleration Jerk rate into high speed for high speed profile.
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RW
RW
0.09
9.8
-
m/s^3
0.7
Basic
0.3
32
ft/s^3
-
2.3
LS23 Deceleration High Speed
Deceleration rate for high speed profile.
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RW
RW
0.09
3.7
-
m/s^2
0.7
Basic
0.29855643
12.00131234
ft/s^2
-
2.299868766
LS24 Deceleration Jerk High Speed
Jerk rate out of high speed into deceleration for high speed profile.
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RW
RW
0.09
9.8
-
m/s^3
0.7
Basic
0.3
32
ft/s^3
-
2.3
LS25 Stop Jerk High Speed
Jerk rate out of deceleration into leveling speed.
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RW
RW
0.09
9.8
-
m/s^3
0.7
Basic
0.3
32
ft/s^3
-
2.3
LS27 High Speed Correction
The amount of leveling distance to be eliminated from a high speed run.
This adjustment can provide additional time running at the run speed after the slowdown
speed has been given to reduce the amount of time at leveling speed. A value of 0 will
have no effect, whereas a value too large may lead to overshooting the floors. When
decelerating from high speed, it is necessary to transition directly from high speed to
leveling. Selecting another speed in between will cancel the function.