EasyManuals Logo

KEB F6 User Manual

KEB F6
305 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
Parameter Descriptions
© 2024 KEB America, Inc.
83
8.2 Basic Setup Parameters (US)
Risk of minor or moderate injury!
Do not change parameters while car is running.
US02 System Units
Motor Type
Setting Options
NUM
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RW
RW
System Units
-
0
1
-
-
1
Basic
m/sec
0
-
-
-
-
-
-
ft/min
1
US03 Motor Type
Selects the motor type and gearing configuration of the system.
Motor Type
Setting Options
NUM
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RW
RW
Motor Type
-
0
1
1
Basic
Induction
0
-
-
-
-
-
-
PM synchronous
1
Changing to a new configuration will return the parameter values to default! If a
new configuration is loaded, a user will need to go through all start-up steps
before running the motor.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB F6 and is the answer not in the manual?

KEB F6 Specifications

General IconGeneral
CategoryInverter
Protection ClassIP20
Communication InterfacesPROFIBUS, CANopen, RS485
Operating Temperature-10°C to +50°C
SeriesF6
Output Frequency0 Hz to 600 Hz
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Short circuit
Humidity5% to 95% (non-condensing)
AltitudeUp to 1000 m above sea level
Control ModesSensorless vector control
Storage Temperature-25°C to +70°C