8.7.3.5 Inspection Speed Profile Rate Settings
LS50 Acceleration Inspection
Acceleration rate for Inspection Speed profile.
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RW
RW
0.09
3.7
-
m/s^2
0.62
Basic
0.3
12.0
ft/s^2
-
2.0
LS51 Start Jerk Inspection
Start Jerk rate into acceleration for Inspection Speed.
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RW
RW
0.09
9.8
-
m/s^3
0.62
Basic
0.3
32.0
ft/s^3
-
2.0
LS52 Acceleration Jerk Inspection
Acceleration Jerk rate into inspection speed for Inspection Profile.
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RW
RW
0.09
9.8
-
m/s^3
0.62
Basic
0.3
32.0
ft/s^3
-
2.0
LS53 Deceleration Inspection
Deceleration rate for Inspection Speed profile. If the enable is dropped when the user
releases the inspection switch, there will be no deceleration.
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RW
RW
0.09
3.7
-
m/s^2
0.62
Basic
0.3
12.0
ft/s^2
-
2.0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB F6 and is the answer not in the manual?

KEB F6 Specifications

General IconGeneral
CategoryInverter
Protection ClassIP20
Communication InterfacesPROFIBUS, CANopen, RS485
Operating Temperature-10°C to +50°C
SeriesF6
Output Frequency0 Hz to 600 Hz
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Short circuit
Humidity5% to 95% (non-condensing)
AltitudeUp to 1000 m above sea level
Control ModesSensorless vector control
Storage Temperature-25°C to +70°C