EasyManua.ls Logo

KEB F6 - Page 188

KEB F6
305 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Descriptions
188
© 2024 KEB America, Inc.
LP01 Position Control
This parameter is used to turn on the One Floor Positioning Control functionality or to
learn the high speed and short floor slowdown distances.
When set to Learn Slowdown, the slowdown for the selected speed (high speed or short
floor) will be measured on the next run. Afterwards, LP01 will automatically be set for

This parameter can zero the elevator position. Setting a value of 3 resets elevator
position to 0.
Motor Type
Setting Options
NUM
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RW
RW
Position Control
-
0
3
-
-
0
Basic
OFF
0
-
-
-
-
-
-
Posi one floor
1
Learn Slowdown
2
Postion value reset
3
LP02 Minimum Slowdown Distance
This parameter shows the minimum required slow down distance, based on the adjusted
profile (acceleration, jerks, high speed) to slow down from contract speed.
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RO
RO
0
6000
-
cm
0
Basic
0
600
in
-
2
LP03 High Speed Slowdown Distance
This value is the actual distance the drive uses to calculate the actual deceleration profile
for high speed runs.
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RW
RW
0
6000
-
cm
0
Basic
0
240
in
-
0
LP04 Short Floor Slowdown Distance
This value is the actual distance the drive uses to calculate the actual deceleration profile
for short floor runs.
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RW
RW
0
6000
-
cm
0
Basic
0
240
in
-
0