LP01 Position Control
This parameter is used to turn on the One Floor Positioning Control functionality or to
learn the high speed and short floor slowdown distances.
When set to Learn Slowdown, the slowdown for the selected speed (high speed or short
floor) will be measured on the next run. Afterwards, LP01 will automatically be set for
This parameter can zero the elevator position. Setting a value of 3 resets elevator
position to 0.
LP02 Minimum Slowdown Distance
This parameter shows the minimum required slow down distance, based on the adjusted
profile (acceleration, jerks, high speed) to slow down from contract speed.
LP03 High Speed Slowdown Distance
This value is the actual distance the drive uses to calculate the actual deceleration profile
for high speed runs.
LP04 Short Floor Slowdown Distance
This value is the actual distance the drive uses to calculate the actual deceleration profile
for short floor runs.