EasyManua.ls Logo

KEB F6 - Page 197

KEB F6
305 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Descriptions
© 2024 KEB America, Inc.
197
DG01 Input Status
Provides the status of the digital input of the F6 Lift drive. The status can be used by the
user for trouble shooting or can be used by the internal functions for further calculations.
Motor Type
Setting Options
NUM
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RO
RO
STO-1
-
0
65535
-
-
0
Basic
STO1
1
-
-
-
-
-
-
STO-2 / SBC
-
STO2
2
SM I3
-
SMI3
4
Reserved
-
Reserved
8
Input 1 (X2A.1)
-
I1
16
Input 2 (X2A.3)
-
I2
32
Input 3 (X2A.5)
-
I3
64
Input 4 (X2A.7)
-
I4
128
Input 5 (X2A.9)
-
I5
256
Input 6 (X2A.11)
-
I6
512
Input 7 (X2A.13)
-
I7
1024
Input 8 (X2A.15)
-
I8
2048
SM BRK-FB1
-
BRKFB1
4096
SM BRK-FB2
-
BRKFB2
8192

Table of Contents