EasyManua.ls Logo

KEB F6 - Page 205

KEB F6
305 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Descriptions
© 2024 KEB America, Inc.
205
DG31 Peak Current
Displays the Peak Current of the VFD.
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RO
RO
-1100
1100
A
-
0
Basic
DG32 Peak Speed
Displays the motor speed in ft/min or m/s.
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RO
RO
0
13
-
m/s
0
Basic
0
2500
ft/min
-
0
DG37 Heatsink Temperature
Displays the temperature of the drive's heatsink in degrees Celsius.
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RO
RO
-3276.7
3276.7
deg C
-
0
Basic
DG38 Motor Temperature
Displays the temperature of the motor in degrees Celsius. This value is measured by a
temperature sensor in the motor connected to the drive's temperature sensor input X1C.9
& X1C.10.
Motor Type
Setting Options
NUM
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RO
RO
temp. acquisition
-
-3276.7
3276.7
deg C
-
0
Basic
PTC closed
-4000
-
-
-
-
-
-
PTC open
4000
no channel
5000
invalid table
7500
short circuit
10000
no connection
20000
invalid value
30000
power unit flash error
32767

Table of Contents