Parameter Descriptions
208
© 2024 KEB America, Inc.
DG49 Signed Elevator Speed
Displays the signed elevator speed.
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RO
RO
-10
10
-
m/s
0
Basic
-2000
2000
ft/min
-
0
DG50 Elevator Speed
Displays the elevator speed.
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RO
RO
0
10
-
m/s
0
Basic
0
2000
ft/min
-
0
DG51 Mode
Provides the current operating state of the F6 Lift.
When the LIFT/US05 is not configured, DG51 will display "255: Not Configured" and a
fault will be displayed in parameter DG90 System Status as well.
Motor Type
Setting Options
NUM
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RO
RO
Lift App State
-
0
255
-
-
0
Basic
Idle
0
-
-
-
-
-
-
MCC Control
1
Enable Voltage
2
Wait Direction
3
Pre-run Checks
4
Open Brake
5
Wait CMD Speed
6
Run
7
Relevel
8
Wait Zero Speed
9
Disable Operation
10
Close Brake
11
Switch Off
12
Disable Voltage
13
Fault
14
Not Configured
255

Table of Contents

Related product manuals