Para.
Name
Adr
Motor Type
Setting Options
Num
Range
Units
Default
Pass
Level
Ind.
PM
Min
Max
Imp.
Met.
LO10
Output Function O2
0x108A
RW
RW
Output Function
-
0
17
-
-
7
Basic
OFF
0
-
-
-
-
-
-
Fault
1
Drive ready
2
Reserved
3
Reserved
4
At speed
5
High speed
6
Deceleration active
7
Speed for door pre-opening
8
Leveling speed
9
Motor Contactor Control
10
Motor overheat
11
Cabinet fan on
12
Condition 1
13
NTSD active
14
Reserved
15
Reserved
16
Brake transistor error
17
LO15
Output Function RLY1
0x108F
RW
RW
Output Function
-
0
17
-
-
0
Basic
OFF
0
-
-
-
-
-
-
Fault
1
Drive ready
2
Reserved
3
Reserved
4
At speed
5
High speed
6
Deceleration active
7
Speed for door pre-opening
8
Leveling speed
9
Motor Contactor Control
10
Motor overheat
11
Cabinet fan on
12
Condition 1
13
NTSD active
14
Reserved
15
Reserved
16
Brake transistor error
17
LO20
Output Function Brake
Control
0x1094
RW
RW
Brake Output Function
-
0
4
-
-
0
Basic
OFF
0
-
-
-
-
-
-
Reserved
1
Reserved
2
Drive on
3
Brake control
4