EasyManua.ls Logo

KEB F6 - Page 283

KEB F6
305 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Reference
© 2024 KEB America, Inc.
283
Para.
Name
Adr
Motor Type
Setting Options
Num
Range
Units
Default
Pass
Level
Ind.
PM
Min
Max
Imp.
Met.
DG01
Input Status
0x1181
RO
RO
STO-1
-
0
65535
-
-
0
Basic
STO1
1
-
-
-
-
-
-
STO-2 / SBC
-
STO2
2
SM I3
-
SMI3
4
Reserved
-
Reserved
8
Input 1 (X2A.1)
-
I1
16
Input 2 (X2A.3)
-
I2
32
Input 3 (X2A.5)
-
I3
64
Input 4 (X2A.7)
-
I4
128
Input 5 (X2A.9)
-
I5
256
Input 6 (X2A.11)
-
I6
512
Input 7 (X2A.13)
-
I7
1024
Input 8 (X2A.15)
-
I8
2048
SM BRK-FB1
-
BRKFB1
4096
SM BRK-FB2
-
BRKFB2
8192
DG02
Inverter Status
0x1182
RO
RO
See Parameter Description
-
0
65535
-
-
0
Basic
DG03
Command Speed
0x1183
RO
RO
-
-
-21474830
21474830
1/min
-
0
Basic
DG04
Elevator Position
0x1184
RO
RO
-
-
-30480
30480
-
cm
0
Basic
-12000
12000
in
-
0
DG05
Actual Torque
0x1185
RO
RO
-
-
-20000
20000
-
Nm
0
Basic
-14760.0295
14760.0295
lbft
-
0
DG06
Motor Current
0x1186
RO
RO
-
-
-1100
1100
A
-
0
Basic
DG07
Motor Speed
0x1187
RO
RO
-
-
-21474830
21474830
1/min
-
0
Basic
DG08
DC Volts
0x1188
RO
RO
-
-
0
1000
-
V
0
Basic
DC Bus Voltage
0
1000
V
-
0
DG09
Magnetizing Current
0x1189
RO
RO
-
-
-3200
3200
A
-
0
Basic
DG10
Modulation Grade
0x118A
RO
RO
-
-
0
110
%
-
0
Basic
DG11
Output Status
0x118B
RO
RO
Output 1 Status
-
0
63
-
-
0
Basic
O1
1
-
-
-
-
-
-
Output 2 Status
-
O2
2
Relay 1 Status
-
RLY1
4
Brake Output Status
-
BRK
8
Software Output Status
-
SWO
16
DG16
Command Torque
0x1190
RO
RO
-
-
-20000
20000
-
Nm
0
Basic
Basic
-14760.0295
14760.0295
lbft
-
0

Table of Contents