Loading...
Parameter Reference
288
© 2024 KEB America, Inc.
Para.
Name
Adr
Motor Type
Setting Options
Num
Range
Units
Default
Pass
Level
Ind.
PM
Min
Max
Imp.
Met.
FB01
Field bus control word
0x1281
RO
RO
Enable
-
0
65535
-
-
0
Basic
0
0
-
-
-
-
-
-
EN
1
Reset
-
0
0
RST
2
Up
-
0
0
UP
4
Down
-
0
0
DWN
8
Bin Speed 1 or Bin Pos 1
-
0
0
BIN1
16
Bin Speed 2 or Bin Pos 2
-
0
0
BIN2
32
Bin Speed 3 or Bin Pos 3
-
0
0
BIN3
64
Reserved or Bin Pos 4
-
0
0
BIN4
128
Reserved or Bin Pos 5
-
0
0
BIN5
256
Fb Special Function 1
-
0
0
SF1
512
Fb Special Function 2
-
0
0
SF2
1024
Fb Special Function 3
-
0
0
SF3
2048
Fb Special Function 4
-
0
0
SF4
4096
Fb Special Function 5
-
0
0
SF5
8192
Fb Special Function 6
-
0
0
SF6
16384
Fb Special Function 7
-
0
0
SF7
32768
reset all inputs
-
none
0
FB02
Field bus speed
0x1282
RO
RO
-
-
-32767
32767
-
-
0
Basic
FB03
Field bus pretorque
0x1283
RO
RO
-
-
-100
100
%
-
0
Basic
FB04
Field bus target position
0x1284
RO
RO
-
-
-2147483647
2147483647
-
-
0
Basic