Method of Control
© 2024 KEB America, Inc.
51
LI03 = B(Level - Correction - Inspection), NUM = 0
US04 = 1
Binary Speed
Selection
Parameter
Control Inputs
I2
I3
I4
S ZERO
-
0
0
0
S LEVELING
LS01
1
0
0
S HIGH
LS02
0
0
1
S INSPECTION
LS03
1
1
0
S CORRECTION
LS04
0
1
0
S INTERMEDIATE 1
LS05
1
0
1
S INTERMEDIATE 2
LS06
0
1
1
S INTERMEDIATE 3
LS07
1
1
1
Symbol:
1 = Input is active
0 = Input is not active
LI03 = B(Inspection - Level - Correction), NUM = 1
US04 = 1
Binary Speed
Selection
Parameter
Control Inputs
I2
I3
I4
S ZERO
-
0
0
0
S LEVELING
LS01
0
1
0
S HIGH
LS02
0
0
1
S INSPECTION
LS03
1
0
0
S CORRECTION
LS04
1
1
0
S INTERMEDIATE 1
LS05
1
0
1
S INTERMEDIATE 2
LS06
0
1
1
S INTERMEDIATE 3
LS07
1
1
1
LI03 = B(Level - Correction - High), NUM = 2
US04 = 1
Binary Speed
Selection
Parameter
Control Inputs
I2
I3
I4
S ZERO
-
0
0
0
S LEVELING
LS01
1
0
0
S HIGH
LS02
1
1
0
S INSPECTION
LS03
0
0
1
S CORRECTION
LS04
0
1
0
S INTERMEDIATE 1
LS05
1
0
1
S INTERMEDIATE 2
LS06
0
1
1
S INTERMEDIATE 3
LS07
1
1
1
LI03 = Decode with LI16
Refer to LI16 Custom Input Decoding.