IEEE-488 Reference
3-57
:FREQuency
:COUPling AC|DC
:COUPling?
:REFerence <n>
:STATe <b>
:STATe?
:ACQuire
:REFerence?
:DIGits <n>
:DIGits?
:SOURce <name>
:SOURce?
:THReshold
:CURRent
:RANGe <n>
:RANGe?
:LEVel <n>
:LEVel?
:VOLTage
:RANGe <n>
:RANGe?
:LEVel <n>
:LEVel?
:TTL
Path to configure frequency:
Specify input coupling.
Query input coupling.
Specify reference (0 to 15e6).
Enable or disable reference.
Query state of reference.
Use input signal as reference.
Query reference value.
Specify measurement resolution (4 or 5).
Query resolution.
Select source: (CURRent or VOLTage).
Query source.
Path to configure threshold:
Path to set current threshold:
Specify range (0 to 1).
Query range.
Specify threshold level.
Query threshold level.
Path to set voltage threshold:
Specify range (0 to 1000).
Query range.
Specify threshold level.
Query threshold level.
Set threshold to TTL level.
AC
0
OFF
5
VOLTage
0.001
0
10
0
3.18.7
3.18.9
3.18.10
3.18.15
3.18.16
:TEMPerature
:APERture <n>
:AUTO <b>
:AUTO ONCE
:AUTO?
:APERture?
:NPLCycles <n>
:AUTO <b>
:AUTO ONCE
:AUTO?
:NPLCycles?
:REFerence <n>
:STATe <b>
:STATe?
:ACQuire
:REFerence?
:DIGits <n>
:AUTO <b>
:AUTO ONCE
:AUTO?
:DIGits?
Path to configure four-wire resistance:
Set integration rate in seconds (166.67e-6 to 1).
Enable or disable auto aperture.
Enable and then disable auto aperture.
Query auto aperture.
Query aperture (integration rate).
Set integration rate (line cycles; 0.01 to 50).
Enable or disable auto NPLC.
Enable and then disable auto NPLC.
Query auto line cycle integration.
Query line cycle integration rate.
Specify reference; -200 to +1821 (°C)
Enable or disable reference.
Query state of reference.
Use input signal as reference.
Query reference value.
Specify measurement resolution (4 to 7).
Enable or disable auto resolution.
Enable and then disable auto resolution.
Query auto resolution.
Query resolution.
(Note 2)
OFF
1
OFF
0
OFF
6
ON
3.18.5
3.18.6
3.18.9
3.18.10
Table 3-10 (Continued)
SENSe command summary
Command Description
Default
parameter SCPI Ref.

Table of Contents

Other manuals for Keithley 2002

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2002 and is the answer not in the manual?

Keithley 2002 Specifications

General IconGeneral
Resolution8.5 digits
DC Voltage Accuracy±0.0006%
Maximum DC Voltage1000 V
Maximum AC Voltage750 V
Maximum DC Current3 A
Maximum AC Current3 A
ConnectivityGPIB, RS-232
DC Voltage Range100 mV to 1000 V
AC Voltage Range100 mV to 750 V
Resistance Range10 Ω to 1 GΩ
Model2002
CategoryMultimeter
InterfaceGPIB, RS-232
AC Current Accuracy±0.1%
Frequency Range0.1Hz to 300kHz
DisplayVFD
TypeDigital
Power Supply100-240V AC, 50/60Hz
Current Range (DC)100 μA to 3 A
Current Accuracy (DC)±0.01%
Current Range (AC)100 μA to 3 A
Current Accuracy (AC)±0.1%
DC Current Range100 μA to 3 A
AC Current Range100 μA to 3 A

Related product manuals