5: SCPI command reference Series 2230G Triple-Channel Power Supplies
5-48 2230G-900-01 Rev. A / June 2018
STATus:QUEStionable:INSTrument:ISUMmary<X>:CONDition?
This command reads the Questionable Instrument Summary Condition Register of the status model for the
specified channel.
Group
Status
Syntax
STATus:QUEStionable:INSTrument:ISUMmary<X>:CONDition?
Arguments
<X> Channel number (1, 2, or 3)
Default value
0
Returns
<NR1> Range: 0 to 255
Example
STAT:QUES:INST:ISUM2:COND?
Queries the Questionable Instrument Summary Condition Register of channel 2.
See also
None
STATus:QUEStionable:INSTrument:ISUMmary<X>:ENABle
This command sets or reads the contents of the Questionable Instrument Summary Event Enable Register of the
status model for the specified channel.
Group
Status
Syntax
STATus:QUEStionable:INSTrument:ISUMmary<X>:ENABle <NR1>
STATus:QUEStionable:INSTrument:ISUMmary<X>:Enable?
Arguments
<X> Channel number (1, 2, or 3)
<NR1> Range 0 to 65535
Default value
0
Returns
<NR1> Range: 0 to 65535 (query form)