Series 2230G
Triple-Channel Power Supplies User's Manual Section 5:
SCPI command reference
2230G-900-01 Rev. A / June 2018 5-29
[SOURce:]CURRent[:LEVel][:IMMediate]:STEP[:INCRement]
This command sets the amount to increase current level. The query version of this command returns the set step
value.
Group
Source
Syntax
[SOURce:]CURRent[:LEVel][:IMMediate]:STEP[:INCRement] <NRf>
[SOURce:]CURRent[:LEVel][:IMMediate]:STEP[:INCRement]?
Arguments
<NRf> The amount to increase the current.
A|mA Unit of measure for the specified current value.
Default Value
0.001 A
Returns
The set step value.
Example
CURR:STEP 0.001A
Increase the current by 1 mA.
See also
None
[SOURce:]CURRent[:LEVel]:UP[:IMMediate][:AMPLitude]
This command increases the current value of the present channel by one step, as specified by the
[SOURce:]CURRent[:LEVel][:IMMediate]:STEP[:INCRement] command.
Group
Source
Syntax
[SOURce:]CURRent[:LEVel]:UP[:IMMediate][:AMPLitude]
Arguments
None
Default value
Not applicable
Returns
Not applicable