5: SCPI command reference Series 2230G Triple-Channel Power Supplies
5-4 2230G-900-01 Rev. A / June 2018
Example
*ESR?
Reads the value of the SESR.
See also
*CLS (on page 5-2)
*OPC (on page 5-5)
*SRE (on page 5-8)
*IDN? (query only)
This command reads information that identifies the power supply. It returns a parameter that contains four
segments divided by a comma. Example: Keithley instruments, 2230G-60-3, 0123456789AF,
1.02-1.06.
Group
Status
Syntax
*IDN?
Arguments
None
Returns
A string with the following segments separated by commas: <manufacturer>, <model>, <serial
number>, and <firmware_version>, in the format shown in the following table.
For example, this command might return the following response for a Model 2230G-60-30 instrument:
Keithley instruments, 2230G-60-3, 0123456789AF, 1.02-1.06
Example
*IDN?
Reads the identifying information for the power supply.
See also
None