Series 2230G
Triple-Channel Power Supplies User's Manual Section 5:
SCPI command reference
2230G-900-01 Rev. A / June 2018 5-11
CALibration subsystem
The commands in the CALibration subsystem are used to configure and control calibration
operations.
CALibrate:CLEar
This command clears the calibration information on the instrument.
Group
Calibration
Syntax
CALibrate:CLEar
Arguments
None
Default value
Not applicable
Returns
Not applicable
Example
CAL:CLE
Clears the calibration information on the instrument.
See also
None
CALibrate:CURRent[:DATA]
This command sets the actual output current value of the calibration point.
Group
Calibration
Syntax
CALibrate:CURRent[:DATA] <NR2>
Arguments
<NR2> Current value of the calibration point.
Default value
Not applicable