EasyManuals Logo

Keithley 2230G-30-3 User Manual

Keithley 2230G-30-3
111 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
Section
3: Function and features Series 2230G Triple-Channel Power Supplies
User's Manual
3-8 2230G-900-01 Rev. A / June 2018
6. Press the down arrow key to select On.
7. Use the numeric keys, the up and down arrow keys, or the navigation wheel to adjust the voltage
value. The value must be less than the rated voltage of the power supply.
8. Press Enter.
9. Press the Esc key to exit the menu.
Set the output timers
You can set the amount of time that the output stays on for each channel. When the OUTPUT On/Off
key is pressed, the timers start and the output is turned on. When each active timer expires, its
corresponding channel output turns off. The timer range is from 0.1 seconds to 99999.9 seconds.
To set the output timers:
1. Press the Menu key.
2. Press the down arrow key to select Protection Settings and press Enter.
3. Press the down arrow key to select Output Timers and press Enter.
4. Use the up and down arrow keys to select the correct channel and press Enter to confirm.
5. Press the down arrow key to select On and press Enter.
6. Use the numeric keys, the up and down arrow keys, or the navigation wheel to adjust the timer.
7. Press Enter.
8. Press the Esc key to exit the menu.
Set the key lock status
You can set the key lock status for each channel in the Protection Settings menu. This function
prevents any adjustments from being made to the instrument. Once the lock is activated, a four-digit,
user-specified password must be entered to change any instrument settings. After the front panel is
locked, only the OUTPUT On/Off key, left and right arrow keys, Channel SELECT (CH1, CH2, CH3),
V-Set, I-Set, and POWER keys function. However, changes to settings cannot be made unless the
password is entered. Turning the power off deactivates the lock and resets the password.
To set the key lock status:
1. Press the Menu key.
2. Press the down arrow key to select Protection Settings.
3. Press Enter.
4. Press the down arrow key to select Key Lock and press Enter.
5. Use numeric keys to input a four-digit password and press Enter.

Table of Contents

Other manuals for Keithley 2230G-30-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2230G-30-3 and is the answer not in the manual?

Keithley 2230G-30-3 Specifications

General IconGeneral
BrandKeithley
Model2230G-30-3
CategoryPower Supply
LanguageEnglish