EasyManuals Logo

Keithley 2230G-30-3 User Manual

Keithley 2230G-30-3
111 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
Section
5: SCPI command reference Series 2230G Triple-Channel Power Supplies
User's Manual
5-18 2230G-900-01 Rev. A / June 2018
INSTrument:COMBine:OFF
This command turns off the connection of channels.
Group
Channel
Syntax
INSTrument:COMbine:OFF
Arguments
None
Default value
Not applicable
Returns
Not applicable
Example
INST:COMB:OFF
Turns off the connection of channels.
See also
INSTrument:COMBine:PARallel (on page 5-18)
INSTrument:COMBine:SERies (on page 5-19)
INSTrument:COMBine:PARallel
This command specifies that the instrument combines the present readings of channels when they are connected
in parallel.
Group
Channel
Syntax
INSTrument:COMBine:PARallel <level>
Arguments
<level> CH1CH2|CH2CH3|CH1CH2CH3 Channels to be combined in parallel
Default value
NONE
Returns
Not applicable

Table of Contents

Other manuals for Keithley 2230G-30-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2230G-30-3 and is the answer not in the manual?

Keithley 2230G-30-3 Specifications

General IconGeneral
BrandKeithley
Model2230G-30-3
CategoryPower Supply
LanguageEnglish

Related product manuals