5: SCPI command reference Series 2230G Triple-Channel Power Supplies
User's Manual
5-18 2230G-900-01 Rev. A / June 2018
INSTrument:COMBine:OFF
This command turns off the connection of channels.
Group
Channel
Syntax
INSTrument:COMbine:OFF
Arguments
None
Default value
Not applicable
Returns
Not applicable
Example
INST:COMB:OFF
Turns off the connection of channels.
See also
INSTrument:COMBine:PARallel (on page 5-18)
INSTrument:COMBine:SERies (on page 5-19)
INSTrument:COMBine:PARallel
This command specifies that the instrument combines the present readings of channels when they are connected
in parallel.
Group
Channel
Syntax
INSTrument:COMBine:PARallel <level>
Arguments
<level> CH1CH2|CH2CH3|CH1CH2CH3 Channels to be combined in parallel
Default value
NONE
Returns
Not applicable